Live Arrival Guarantee on all fish · 5★ Google Rated
The unique design and robust construction of the G2 Heat Exchanger offers an unrivalled heat transfer surface area, making it one of the most efficient products on the market.
Features & Benefits
| Product Code: | Standard Power Output: | Dimension ‘L1’ | Dimension ‘L2’ | Dimension ‘L3’ | Net Weight | Gross Weight | Volume | ||||
| [mm] | [mm] | [mm] | [kg] | [kg] | [m³] | ||||||
| G2-HE-30T | 30-kW (102K BTU) | 540 | 426 | 247 | 3.5 | 3.9 | 0.016 | ||||
| G2-HE-49T | 49-kW (167K BTU) | 710 | 596 | 417 | 4.5 | 5.0 | 0.021 | ||||
| G2-HE-85T | 85-kW (290K BTU) | 840 | 726 | 547 | 5.3 | 6.3 | 0.026 | ||||
| G2-HE-122T | 122-kW (416K BTU) | 1000 | 886 | 707 | 6.4 | 7.6 | 0.037 | ||||
| Standrad Output: | Primary Flow [m³/h] | Primary Pressure Loss [Bar] | Secondary Flow [m³/h] | Secondary Pressure Loss [Bar] | DT 15°C [kW] | DT 20°C [kW] | DT 30°C [kW] | DT 40°C [kW] | DT 50°C [kW] | DT 60°C [kW] | DT 70°C [kW] |
| 30-kW | 1.1 | 0.061 | 10 | 0.050 | 9 | 11 | 16 | 20 | 26 | 30 | 33 |
| 30-kW | 1.3 | 0.068 | 10 | 0.050 | 10 | 13 | 18 | 23 | 31 | 34 | 39 |
| 30-kW | 1.3 | 0.068 | 14 | 0.070 | 11 | 15 | 20 | 26 | 34 | 41 | 46 |
| 49-kW | 1.6 | 0.077 | 16 | 0.092 | 13 | 18 | 25 | 43 | 41 | 50 | 56 |
| 49-kW | 1.8 | 0.083 | 16 | 0.092 | 15 | 20 | 28 | 38 | 45 | 55 | 62 |
| 49-kW | 2.2 | 0.093 | 17 | 0.098 | 16 | 22 | 33 | 44 | 52 | 64 | 73 |
| 85-kW | 2.4 | 0.113 | 17 | 0.106 | 22 | 28 | 40 | 53 | 64 | 75 | 81 |
| 85-kW | 2.7 | 0.129 | 17 | 0.106 | 26 | 32 | 46 | 60 | 73 | 82 | 89 |
| 85-kW | 3.2 | 0.147 | 17 | 0.106 | 28 | 34 | 49 | 64 | 77 | 90 | 102 |
| 122-kW | 3.8 | 0.183 | 19 | 0.126 | 33 | 43 | 68 | 75 | 93 | 108 | 120 |
| 122-kW | 4.2 | 0.200 | 19 | 0.126 | 36 | 48 | 70 | 89 | 108 | 126 | 143 |
| 122-kW | 4.6 | 0.211 | 19 | 0.126 | 38 | 53 | 73 | 95 | 116 | 137 | 156 |